Configure NetFlow Settings

NetFlow is a network analysis tool that you can use to monitor network monitoring and virtual machine traffic.

NetFlow is available on vSphere distributed switch version 5.0.0 and later.

Procedure

1 Log in to the vSphere Client and select the Networking inventory view.

2 Right-click the vSphere distributed switch in the inventory pane, and select Edit Settings.

3 Navigate to the NetFlow tab.

SNAGHTML5f0203b

The sampling rate determines what portion of data, NetFlow collects, with the sampling rate number

determining how often NetFlow collects the packets. A collector with a sampling rate of 2 collects data

from every other packet. A collector with a sampling rate of 5 collects data from every fifth packet.

9 Click OK.

How to enable Port Mirroring

Working With Port Mirroring

Port mirroring allows you to mirror a distributed port’s traffic to other distributed ports or specific physical

switch ports.

Create a Port Mirroring Session

Create a port mirroring session to mirror vSphere distributed switch traffic to specific physical switch ports.

Prerequisites

Needs a vSphere distributed switch version 5.0.0 or later.

 

Specify Port Mirroring Name and Session Details

Specify the name, description, and session details for the new port mirroring session.

Procedure

1 Log in to the vSphere Client and select the Networking inventory view.

2 Right-click the vSphere distributed switch in the inventory pane, and select Edit Settings.

3 On the Port Mirroring tab, click Add.

SNAGHTML59c7339

4 Enter a Name and Description for the port mirroring session.

SNAGHTML5a5d7a6

Click Next.

Choose Port Mirroring Destinations

SNAGHTML5acdcd4

Click Next.

Choose Port Mirroring Destinations

Select Port, or uplink as destinations for the port mirroring session.

Port Mirroring is checked against the VLAN forwarding policy. If the VLAN of the original frames is not equal to or trunked by the destination port, the frames are not mirrored.

 

image

You can optionally enable port mirroring now or later now.

SNAGHTML5b7ceff

 

SNAGHTML5b96258

How to enable IPv6 on vSphere

Please note IPv6 is disabled by default.

Prerequisites

Required privilege: Host.Configuration.Network Configuration

Procedure

1 From the vSphere Client Home page, click Hosts and Clusters.

2 Select the host and click the Configuration tab.

3 Click the Networking link under Hardware.

image

4 In the vSphere Standard Switch view, click the Properties link.

image

5 Select Enable IPv6 support on this host system and click OK.

SNAGHTML5f98229

6 Reboot the host.

How to Manage Policies for Multiple Port Groups on a vDS

You can modify networking policies for multiple port groups on a distributed switch.

Prerequisites

Create a vSphere distributed switch with one or more port groups.

Procedure

1 Log in to the vSphere Client and select the Networking inventory view.

2 Right-click the distributed switch and select Manage Port Groups.

image

3 Select the policy categories to modify.

SNAGHTML22ca04f

For purpose of this discussion let’s select Teaming and Failover policy

So next screen are specific to Teaming and Failover policy only.

SNAGHTML22f7f67

 

SNAGHTML2324d5f

 

SNAGHTML23348fc

How to block Port Blocking in vDS

Port blocking policies allow you to selectively block ports from sending or receiving data.

Port Blocking Policy for a Distributed Port Group

The Miscellaneous policies dialog allows you to configure various distributed port group policies.

Procedure

1 Log in to the vSphere Client and select the Networking inventory view.

2 Right-click the distributed port group in the inventory pane, and select Edit Settings.

3 Select Policies.

SNAGHTML2201bd4

4 In the Miscellaneous group, choose whether to Block all ports in this distributed port group.

5 Click OK.

How to enable NetFlow

Monitoring Policy

The monitoring policy enables or disables NetFlow monitoring on a distributed port or port group.

NetFlow settings are configured at the vSphere distributed switch level.

Edit the Monitoring Policy on a Distributed Port Group

With the Monitoring policy, you can enable or disable NetFlow monitoring on a distributed port group.

Procedure

1 Log in to the vSphere Client and select the Networking inventory view.

2 Right-click the distributed port group in the inventory pane, and select Edit Settings.

3 Select Policies.

4 In the Monitoring group, select the NetFlow Status from the drop down menu.

SNAGHTML218da42

5 Click OK

Edit the Resource Allocation Policy on a Distributed Port

Associate a distributed port with a network resource pool to give you greater control over the bandwidth given to the port.

Prerequisites

Enable Network I/O Control on the host and create one or more user-defined network resource pools.

Procedure

1. Log in to the vSphere Client and select the Networking inventory view.

2. Select the vSphere distributed switch in the inventory pane.

3. On the Ports tab, right-click the port to modify and select Edit Settings.

SNAGHTML21150f7

 

4. Select Policies.

5. In the Resource Allocation group, select the Network Resource Pool to associate the port with from the drop-down menu.

SNAGHTML20e8e73

6. Click OK.

Notes for Storage Guide 02

For Guide 01 click here

 

NetFlow is a network analysis tool that you can use to monitor network monitoring and virtual machine traffic.

NetFlow is available on vSphere distributed switch version 5.0.0 and later.

 

Switch discovery protocols allow vSphere administrators to determine which switch port is connected to a given vSphere standard switch or vSphere distributed switch.

 

vSphere 5.0 supports Cisco Discovery Protocol (CDP) and Link Layer Discovery Protocol (LLDP).

CDP is available for both vSphere standard switches and vSphere distributed switches connected to Cisco physical switches.

LLDP is only available for vSphere distributed switches version 5.0.0 and later.

 

When CDP or LLDP is enabled for a particular vSphere distributed switch or vSphere standard switch,

you can view properties of the peer physical switch such as device ID, software version, and timeout from the vSphere Client.

 

Enable Cisco Discovery Protocol on a vSphere Distributed Switch

 

Procedure

1.      Log in to the vSphere Client and select the Networking inventory view.

2.      Right-click the vSphere distributed switch in the inventory pane, and select Edit Settings.

3.      On the Properties tab, select Advanced.

4.      Select Enabled from the Status drop-down menu.

5.      Select Cisco Discovery Protocol from the Type drop-down menu.

 

image

 

6.      Select the CDP mode from the Operation drop-down menu.

7.      Click OK.

 

SNAGHTML34cbf6

 

 

MAC Addresses

 

MAC addresses are generated for virtual network adapters that virtual machines and network services use.

In most cases, the generated MAC addresses are appropriate. However, you might need to set a MAC address

for a virtual network adapter, as in the following cases:

·         Virtual network adapters on different physical hosts share the same subnet and are assigned the same

        MAC address, causing a conflict.

·         To ensure that a virtual network adapter always has the same MAC address.

To circumvent the limit of 256 virtual network adapters per physical machine and possible MAC address conflicts

between virtual machines, system administrators can manually assign MAC addresses.

 

By default, VMware uses the Organizationally Unique Identifier (OUI) 00:50:56 for manually generated

addresses, but all unique manually generated addresses are supported.

 

You can set the addresses by adding the following line to a virtual machine‘s configuration file:

ethernetnumber.address = 00:50:56:XX:YY:ZZ

 

where <number> refers to the number of the Ethernet adapter,

XX is a valid hexadecimal number between 00 and 3F (in decimal it is 63),

and YY and ZZ are valid hexadecimal numbers between 00 and FF(in decimal it is 255).

 

The value for XX must not be greater than 3F to avoid conflict with MAC addresses that are generated

by the VMware Workstation and VMware Server products.

 

The maximum value for a manually generated MAC address is:

ethernetnumber.address = 00:50:56:3F:FF:FF (in decimal 00:50:56:63:255:255)

 

You must also set the option in a virtual machine’s configuration file:

 

ethernetnumber.addressType=”static”

 

The first three bytes of the MAC address that is generated for each virtual network adapter consists of the OUI.

The MAC address-generation algorithm produces the other three bytes. The algorithm guarantees unique

MAC addresses within a machine and attempts to provide unique MAC addresses across machines.

The network adapters for each virtual machine on the same subnet should have unique MAC addresses.

Otherwise, they can behave unpredictably. The algorithm puts a limit on the number of running and suspended

virtual machines at any one time on any given host. It also does not handle all cases when virtual machines on

distinct physical machines share a subnet.

 

Who is responsible for generating MAC addresses in vSphere environment?

The VMware Universally Unique Identifier (UUID) generates MAC addresses that are checked for conflicts.

 

The generated MAC addresses are created by using three parts: the VMware OUI, the SMBIOS UUID for the physical ESXi machine, and a hash based on the name of the entity that the MAC address is being generated for.

 

When does MAC address changes?

After the MAC address has been generated, it does not change unless the virtual machine is moved to a different location, for example, to a different path on the same server. The MAC address in the configuration file of the virtual machine is saved.

 

 

All MAC addresses that have been assigned to network adapters of running and suspended virtual machines on a given physical machine are tracked. The MAC address of a powered off virtual machine is not checked against those of running or suspended virtual machines. It is possible that when a virtual machine is powered on again, it can acquire a different MAC address. This acquisition is caused by a conflict with a virtual machine that was powered on when this virtual machine was powered off.

 

For Guide 01 click here

Notes for Storage Guide 01

Load Balancing and Failover Policy

 

You can edit your load balancing and failover policy by configuring the following parameters:

 

Load Balancing policy determines how outgoing traffic is distributed among the network adapters associated

with a switch or port group.

 

NOTE Incoming traffic is controlled by the load balancing policy on the physical switch.

 

Failover Detection controls the link status and beacon probing.

Beaconing is not supported with guest VLAN tagging.

 

Network Adapter Order can be active or standby.

List down one of the reason why you should enable port fast

In some cases, you might lose standard switch connectivity when a failover or failback event occurs.

This causes the MAC addresses used by virtual machines associated with that standard switch

to appear on a different switch port than they previously did. To avoid this problem, put your

physical switch in portfast or portfast trunk mode

 

In network detection failover detection, what are the limitations of “Link Status Only”

This policy does not detect configuration errors, such as a physical switch port being blocked by

spanning tree or misconfigured to the wrong VLAN or cable pulls on the other side of a

physical switch. This policy relies solely on the link status that the network adapter provides.

This option detects only failures, such as cable pulls and physical switch power failures.

 

 

In network detection failover detection, when it is recommended not to use beacon Probing

It is recommend not using beacon probing when you are using IP hash load balancing policies.

Beacon probing sends out and listens for beacon probes on all NICs in the team and uses this

information, in addition to link status, to determine link failure. This option detects many of

the failures mentioned above that are not detected by link status alone.

 

image

 

In almost all cases, Notify Switches policy is set to Yes as it is desirable for the lowest

latency of failover occurrences and migrations with vMotion. But there is one use case

where it is recommended setting Notify Switches to No?

=>If you are going to use Microsoft Network Load Balancing in unicast mode, it is recommended

to set this option to No.

 

When you select Yes, whenever a virtual NIC is connected to the standard switch or whenever

that virtual NIC’s traffic is routed over a different physical NIC in the team because of a failover

event, a notification is sent over the network to update the lookup tables on the physical switches.

 

In which two cases you should not keep any network adapter in Standby Adapters list

=>When you are using iSCSI Multipathing, your VMkernel interface must be configured to have

one active adapter and when using IP-hash load balancing.

 

Security Policy

 

Networking security policies determine how the adapter filters inbound and outbound frames.

The three elements of the security policy are promiscuous mode; MAC address changes, and forged transmits.

 

In nonpromiscuous mode, a guest adapter listens only to traffic forwarded to own MAC address.

In promiscuous mode, it can listen to all the frames. By default, guest adapters are set to nonpromiscuous mode.

 

In Mac Address Changes - If you set the MAC Address Changes to Reject and the guest operating system

changes the MAC address of the adapter to anything other than what is in the .vmx configuration file,

all inbound frames are dropped.

 

In Forget Transmits - Any outbound frame with a source MAC address that is different from the

one currently set on the adapter are dropped.

 

Traffic Shaping Policy

 

A traffic shaping policy is defined by average bandwidth, peak bandwidth, and burst size.

You can establish a traffic shaping policy for each port group and each distributed port or distributed port group.

 

ESXi shapes outbound network traffic on standard switches and inbound and outbound traffic on distributed switches.

 Traffic shaping restricts the network bandwidth available on a port, but can also be configured to

allow bursts of traffic to flow through at higher speeds.

 

 

 

 

image

 

The Status policy here is applied to each virtual adapter attached to the port group, not to the standard switch

as a whole. If you enable the policy exception in the Status field, you set limits on the amount of networking

bandwidth allocation for each virtual adapter associated with this particular port group. If you disable the

policy, services have a clear connection to the physical network by default.

Enabling Jumbo Frames

Jumbo frames allow ESXi to send larger frames out onto the physical network. The network must support jumbo frames end-to-end. Jumbo frames up to 9kB (9000 bytes) are supported. Before enabling Jumbo frames, check with your hardware vendor to ensure that your physical network adapter supports jumbo frames.

Enable Jumbo Frames for a VMkernel Interface on a vSphere Standard Switch

Jumbo frames reduce the CPU load caused by transferring data. Enable jumbo frames on a VMkernel network interface by changing the maximum transmission units (MTU) of the VMkernel interface.

Procedure

1. Log in to the vSphere Client and select the Hosts and Clusters inventory view.

2. On the host Configuration tab, click Networking.

3. Click Properties for the vSphere standard switch associated with the VMkernel to modify.

4. On the Ports tab, select the VMkernel interface and click Edit.

SNAGHTMLc61e724

5. Set the MTU to 9000, and click OK.

SNAGHTMLc5f7f2e

Enable Jumbo Frames on a vSphere Distributed Switch

Enable a vSphere distributed switch for jumbo frames by changing the MTU size for that distributed switch.

Procedure

1. Log in to the vSphere Client and select the Networking inventory view.

2. Right-click the vSphere distributed switch in the inventory pane, and select Edit Settings.

image

3. On the Properties tab, select Advanced.

4. Set the Maximum MTU to the largest MTU size among all the virtual network adapters connected to the vSphere distributed switch, and click OK.

SNAGHTMLc74706f

 

image